  gnt30 medical series single output power supply ? 90-264 vac input range ? overvoltage and short circuit protection ? approved to ul, csa and en standards ? small 50 mm x 80 mm footprint ? class ii input available (g2t30) the gnt30 series is a 30 w universal input ac/dc power supply in a very small footprint. with the medical approvals the gnt30 is ideal for a variety of medical device applications including, small single board computers, battery charging, and running small motors, pumps, and solenoids. the series with full approval to en60601-1 standard improves design-in time, and reduces end system compliance costs. input specifications input voltage range universal input 100-240 nom (90 - 264 max) vac input frequency 55 hz +/- 10 hz input surge current 32 a max. ground leakage current 132 vac 60 hz 100 m a (180 m a single fault) input current 120 vac 0.6 a 230 vac 0.37 a input fuse f1,f2 2.5 a emc information conducted emissions en55011 level b radiated emissions en55011 level a line freq. harmonics en61000-3-2 complies voltage fuctuations en61000-3-3 complies esd air en61000-4-2 8 kv contact esd contact en61000-4-2 6 kv air radiated immunity en61000-4-3 3 v/m fast transients (eft) en61000-4-4 2 kv line surge immunity en61000-4-5 1 kv diff /2 kv cm conducted immunity en61000-4-6 3 v rms power freq. mag. feld en61000-4-8 3 a/m voltage dip immunity en61000-4-11 5 cycles 40 % vnom 0.5 watts. 25 cycles 70 % vnom 20 w environmental specifications thermal performance operating ambient (see chart) 0-50 o c non-operating -40 to +85 o c 0 - 50 o c 150 l.f.m (see note 4.) 30 watts 50 -70 o c ambient 150 l.f.m derate 2% / o c relative humidity non-condensing 0% - 95% rh maximum altitude operating / non-operating 10,000 ft. / 40,000 ft. max. vibration operating non-operating 1.5 g rms 20-2000 hz 5 g rms 20-2000 hz shock operating non-operating 20 g pk 10 ms, half-sine 40 g pk 10 ms half-sine ouput specifications output power 150 l.f.m. airfow 30 watts max.(see note 4 total regulation see table turn-on time 1.5 s max. transient response 0.25 a/ms 50% load deviation 3.5% max. dev. 1 ms recovery to 1% temperature coef - fcient +/-0.03%/oc overvoltage protection 125% +/-10% short circuit protection power cycling yes all specifcations are typical at nominal input, full load at 25 o c unless otherwise stated specifications low power medical power supplies 30 watt ac/dc universal input power supply summary
general specifications hold-up time 120 vac, 60 hz 16 ms at 30 watts output effciency 120 vac 30 w output >78 % isolation voltage input to ouput input to ground 4000 vac 1500 vac switching frequency fxed 120 khz, +/- 5 khz safety approvals ul/en/iec 60601-1 csa22.2 no.601 ul/en/iec 60950-1 csa22.2 no.60950-1 maximum weight 100 g (0.22 lbs) model number 40 o c convection 50 o c convection 50 o c airfow ripple regulation gnt30-5 5 v 4.0 a 5 v 3.2 a 5 v 6.0 a 50 mv 2% GNT30-12 12 v 2.5 a 12 v 1.66 a 12 v 2.5 a 120 mv 2% gnt30-15 15 v 2.0 a 15 v 1.06 a 15 v 2.0 a 150 mv 2% gnt30-24 24 v 1.25 a 24 v 0.83 a 24 v 1.25 a 240 mv 2% gnt30-28 28 v 1.07 a 28 v 0.8 a 28 v 1.07 a 280 mv 2% gnt30-48 48 v 0.625 a 48 v 0.416 a 48 v 0.625 a 480 mv 2% notes 1. when the input voltage is less than 90 vac the operating temperature range is 0 o c to 40 o c. the ripple and regulation specs. may not be met. 2. peak output current rating is for 1 minute and 10 % duty cycle. 3. heatsink temperatures should not be allowed to exceed 90 o c 4. output voltage is adjustable +/- 5% of nominal. see installation instructions (www.condorpower.com) mechanical notes input j1 amp p/n 640456-3 tb1 pin 1 ac line pin 1 ac line pin 2 n/c pin 2 ac neutral pin 3 ac neutral 0.187 faston ground ground output j2 amp p/n 640456-4 tb2 pin 1 common pin 1 common pin 2 common pin 2 output 1 pin 3 output 1 pin 4 output 1 condor dc power supplies inc. 2311 statham parkway, oxnard ca, 93033, usa. phone:(805) 486 4565 fax:(805) 487 8911 email: condor@condordc.com gnt30 rev h 11/11/05. data sheet ? 2005 condor dc power supplies inc. the information and specifcations contained in this data sheet are believed to be correct at time of publication. however, condor accepts no responsibility for consequences arising from reproduction errors or inaccuracies. specifcations are subject to change without notice. mating connectors contact input housing 1375820-3 1375819-1 output housing 1375820-4 1375819-1


▲Up To Search▲   

 
Price & Availability of GNT30-12

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X